Bilaney Consultants, basé en Allemagne et au Royaume-Uni, fournit des équipements et des logiciels de recherche de qualité aux chercheurs en sciences de la vie et aux chercheurs biomédicaux en Europe depuis 1966. N'hésitez pas à nous contacter si vous avez des questions sur le produit ou si vous avez besoin d'assistance.

Catalogue des produits

CMA 7 Microdialysis Probes

SKU CMA 7 Microdialysis Probes
0,00€
In stock
1
Product Details

NEW! CMA 7 PROBES FOR BIG MOLECULES!

The CMA 7 Microdialysis Probe is ideal for use in small areas of the brain or spinal cord of small animals. It is especially suitable for studies in transgenic mice.

  • Extremely small
  • Optimized for CNS use
  • Ideal for chronical implantation
  • Membrane lengths: 1 or 2 mm
  • Membrane diameter: 0.24 mm (6 kDa), 0.26 mm (55 kDa) or 0.28 mm (500 kDa or 2 MDa)
  • Available metal free or β-irradiated

Item Listing

Item# Description
CMAP000082 CMA 7 6 kDa Microdialysis Probe, 1 mm membrane length (pkg. of 3)
CMAP000083 CMA 7 6 kDa Microdialysis Probe, 2 mm membrane length (pkg. of 3)
CMA8010771 CMA 7 6 kDa Metal Free Microdialysis Probe, 1 mm membrane length (pkg. of 3)
CMA8010772 CMA 7 6 kDa Metal Free Microdialysis Probe, 2 mm membrane length (pkg. of 3)
CMA8010681 CMA 7 6 kDa β-Irradiated Microdialysis Probe, 1 mm membrane length (pkg. of 3)
CMA8010682 CMA 7 6 kDa β-Irradiated Microdialysis Probe, 2 mm membrane length (pkg. of 3)
CMA8012411 CMA 7 55 kDa Microdialysis Probe, 1 mm membrane length, pkg. of 3
CMA8012412 CMA 7 55 kDa Microdialysis Probe, 2 mm membrane length, pkg. of 3
CMA8012421 CMA 7 500 kDa Microdialysis Probe, 1 mm membrane length, pkg. of 3
CMA8012422 CMA 7 500 kDa Microdialysis Probe, 2 mm membrane length, pkg. of 3
CMA8012423 CMA 7 2 MDa Microdialysis Probe, 1 mm membrane length, pkg. of 3
CMA8012424 CMA 7 2 MDa Microdialysis Probe, 2 mm membrane length, pkg. of 3

NEW! CMA 7 PROBES FOR BIG MOLECULES!

The CMA 7 Microdialysis Probe is ideal for use in small areas of the brain or spinal cord of small animals. It is especially suitable for studies in transgenic mice.

The construction and geometry of the CMA 7 6 kDa Microdialysis Probe tip is exactly the same as in the CMA 11. The outer diameter is 0.24 mm and the shaft length is 7 mm.

New CMA 7 microdialysis probes are now available with 55 kDa cut-off and 0.26 mm outer diameter (more details in the Specifications section).

New CMA 7 microdialysis probes for big molecules are also now available with 500 kDa and 2 MDa cut-off, 0.28 mm outer diameter and 14 mm shaft length (more details in the Specifications section).

An extremely small plastic body where the inlet and outlet tubing are directly mounted, makes the probe easy to implant and light for a small animal to carry. A matching small and lightweight guide cannula is available.

Standard part numbers are available for metal free or β-irradiated CMA 7 6 kDa probes.

For metal free or β-irradiated CMA 7 55 kDa, 500kDa and 2MDa probes, please make your request using our Custom Probe Form and send it to our Technical Support Team. We will contact you promptly.

CMA 7 Microdialysis Probes are guaranteed for single use.

Specifications

Specifications CMAP000082 CMAP000083 CMA8010771 CMA8010772 CMA8010681 CMA8010682 CMA8012411 CMA8012412 CMA8012421 CMA8012422 CMA8012423 CMA8012424
Membrane Length 1 mm 2 mm 1 mm 2 mm 1 mm 2 mm 1 mm 2 mm 1 mm 2 mm 1 mm 2 mm
Membrane O D 0.24 mm 0.24 mm 0.24 mm 0.24 mm 0.24 mm 0.24 mm 0.26 mm 0.26 mm 0.28 mm 0.28 mm 0.28 mm 0.28 mm
Membrane Material Cuprophane Cuprophane Cuprophane Cuprophane Cuprophane Cuprophane Polyestersulfone (PES) Polyestersulfone (PES) Polyestersulfone (PES) Polyestersulfone (PES) Polyestersulfone (PES) Polyestersulfone (PES)
Molecular Weight Cut-off 6 kD 6 kD 6 kD 6 kD 6 kD 6 kD 55 kD 55 kD 500 kD 500 kD 2 MDa 2 MDa
Shaft Diameter 0.38 mm 0.38 mm 0.38 mm 0.38 mm 0.38 mm 0.38 mm 0.40 mm 0.40 mm 0.40 mm 0.40 mm 0.40 mm 0.40 mm
Shaft Length Metric 7 mm 7 mm 7 mm 7 mm 7 mm 7 mm 7 mm 7 mm 14 mm 14 mm 14 mm 14 mm
Inlet Volume negligible negligible negligible negligible negligible negligible 0.06 µL 0.06 µL 0.06 µL 0.06 µL 0.06 µL 0.06 µL
Outlet Volume 0.3 µL 0.3 µL 0.3 µL 0.3 µL 0.3 µL 0.3 µL 0.3 µL 0.3 µL 0.3 µL 0.3 µL 0.3 µL 0.3 µL
200 mm Inlet tubing (blue) 3.5 µL 3.5 µL 3.5 µL 3.5 µL 3.5 µL 3.5 µL 3.6 µL 3.6 µL 3.5 µL 3.5 µL 3.5 µL 3.5 µL
200 mm Outlet tubing (transp.) 3.5 µL 3.5 µL 3.5 µL 3.5 µL 3.5 µL 3.5 µL 3.6 µL 3.6 µL 3.5 µL 3.5 µL 3.5 µL 3.5 µL
Model Standard Standard Metal Free Metal Free β-Irradiated β-Irradiated Standard Standard Standard Standard Standard Standard

Journal Articles

Yau JL, Noble J, Kenyon CJ, Ludwig M, Seckl JR. (2015 ) Diurnal and stress-induced intra-hippocampal corticosterone rise attenuated in 11β-HSD1-deficient mice: a microdialysis study in young and aged mice. Eur J Neurosci.

Pawlisch BA, Remage-Healey L. (2015 ) Neuroestrogen signaling in the songbird auditory cortex propagates into a sensorimotor network via an 'interface'nucleus Neuroscience.

Dall, C. et al., 2017. Muscarinic receptor M4 positive allosteric modulators attenuate central effects of
cocaine. Drug and Alcohol Dependence, 176, pp.154–161.

Chen, X. et al., 2017. Influence of peptide transporter 2 (PEPT2) on the distribution of cefadroxil in mouse
brain: A microdialysis study. Biochemical Pharmacology, 131, pp.89–97.

Bank, J.H.H. et al., 2017. Gene expression analysis and microdialysis suggest hypothalamic triiodothyronine
(T3) gates daily torpor in Djungarian hamsters (Phodopus sungorus). Journal of Comparative Physiology B,
pp.1–12.

Ramírez-Jarquín, U.N. et al., 2017. Chronic infusion of SOD1G93A astrocyte-secreted factors induces spinal
motoneuron degeneration and neuromuscular dysfunction in healthy rats. Journal of Cellular Physiology,
p.n/a-n/a.

Yoshimoto, K. et al., 2017. Enhanced alcohol-drinking behavior associated with active cholinergic and
serotoninergic neurons in the lateral hypothalamus and amygdala. Pharmacology Biochemistry and
Behavior, 153, pp.1–11.

Ramírez-Jarquín, U.N. & Tapia, R., 2017. Chronic GABAergic blockade in the spinal cord in vivo induces
motor alterations and neurodegeneration. Neuropharmacology, 117, pp.85–92.

Moreno-Castilla, P. et al., 2017. Hippocampal release of dopamine and norepinephrine encodes novel
contextual information. Hippocampus, 27(5), pp.547–557.

Rapanelli, M. et al., 2017. Histamine H3R receptor activation in the do rsal striatum triggers stereotypies in a
mouse model of tic disorders. Translational Psychiatry, 7(1), p.e1013.

Pham, T.H. et al., 2017. Ketamine treatment involves medial prefrontal cortex serotonin to induce a rapid
antidepressant-like activity in BALB/cJ mice. Neuropharmacology, 112, Part A, pp.198–209.

Callan, S.P. et al., 2017. Toluene’s effects on activity and extracellular dopamine in the mouse are altered by
GABAA antagonism. Neuroscience Letters, 647, pp.67–71.

Save this product for later

EndNote - Recherche plus intelligente

Endnote est le leader mondial des programmes de gestion de la littérature. Des millions de scientifiques, d'étudiants, de bibliothécaires et d'auteurs utilisent déjà Endnote. Effectuer des recherches dans les bases de données bibliographiques et organiser les sources de documentation, les références et les images. Bilaney Consultants vend du matériel et des logiciels de recherche aux scientifiques depuis 1966 et est le distributeur autorisé en Allemagne, en Autriche et au Royaume-Uni. Nous nous réjouissons d'avoir de vos nouvelles

Avec EndNote X9, vous pouvez laisser derrière vous le travail fastidieux de formatage des bibliographies, de recherche de texte intégral et de recherche de références.

Acheter EndNote X9

David Kopf Instruments

Systèmes stéréotaxiques - David Kopf Instruments conçoit et fabrique une gamme complète d'instruments et d'accessoires stéréotaxiques de haute qualité pour la recherche neurophysiologique. Micropositionneurs - haute précision et fiabilité de Daivd Kopf Instruments, le leader depuis plus de 50 ans.

Actimetrics

L'actimétrie permet de réaliser des systèmes automatisés pour l'expérimentation comportementale animale, elle met l'accent sur la facilité d'utilisation et l'application des techniques modernes de traitement du signal et de l'image aux problèmes actuels des neurosciences. Des dizaines de fonctionnalités conçues pour la collecte et l'analyse de données à haut débit profitent aussi bien aux grands qu'aux petits utilisateurs.

Coulbourn Instruments

Depuis 40 ans, Coulbourn Instruments fournit des instruments de recherche comportementale et physiologique de qualité aux plus grands scientifiques du monde entier. Systèmes complets intégrés matériel/logiciel pour des études in vivo en toxicologie, pharmacologie et neurosciences pour l'apprentissage et la mémoire, l'activité, l'anxiété, la dépendance, le métabolisme, la peur contextuelle, la sursaut acoustique, les rythmes circadiens, le dépistage des drogues et plus encore.

Endnote X9

C'est pour plus que des bibliographies. Synchronisez votre bibliothèque EndNote sur votre bureau, votre iPad et en ligne. Travaillez vos recherches de n'importe où. Effectuez des recherches dans des bases de données en ligne, recueillez des articles en texte intégral et complétez automatiquement vos références. Organisez, stockez et annotez vos fichiers de recherche de la manière qui vous convient le mieux. Notre service d'appariement de revues vous suggère les meilleures revues possibles pour publier votre manuscrit de recherche. Utilisez le générateur de bibliographie intégré pour créer et formater des citations dans plus de 6 000 styles. Collaborez en ligne au sein de votre propre équipe et avec la communauté de recherche mondiale.

San Diego Instruments

Depuis plus de 30 ans, San Diego Instruments sert la communauté scientifique en tant que ressource complète pour la conception, la fabrication et la distribution d'instruments de recherche en neuroscience comportementale utilisés dans les études humaines et animales. Utilisés dans les laboratoires et cités dans les rapports de recherche du monde entier, les systèmes SDI sont devenus la norme de l'industrie en matière de qualité et de longévité. Notre premier SR-LAB™ est le système de réponse à la sursaut le plus utilisé au monde.

Plastics One

Vous passez un temps précieux à construire vos propres pièces pour la recherche préclinique ? Tu sais que tu n'as pas à le faire ? Des canules de perfusion et des systèmes électrophysiologiques aux composants optogénétiques en passant par les besoins de la recherche invivo, PlasticsOne connaît bien l'importance de la recherche préclinique en neurosciences de première ligne pratiquée par les scientifiques du monde entier. Après tout, nous sommes en partenariat avec plusieurs d'entre vous depuis plus de 30 ans !

iWorx

iWorx offre une famille complète de kits d'enseignement TA (Teaching Assistant) faciles à utiliser pour la physiologie humaine, animale, de l'exercice et psychologique ainsi que la neurobiologie. Les kits fournissent tous les instruments, logiciels et didacticiels développés par des professionnels pour effectuer des centaines d'expériences et d'exercices en laboratoire de niveau collégial.

Innovassynth

Innovassynth Technologies (India) Limited a conclu des partenariats très fructueux avec plusieurs sociétés mondiales prestigieuses à travers le monde depuis sa création. Nos clients mondiaux bénéficient d'un avantage concurrentiel énorme grâce à la réduction du délai nécessaire pour franchir les étapes du développement progressif et, enfin, pour lancer le produit sur le marché. La société a identifié NUCLEOSIDES comme un créneau de niche et s'est forgé une réputation de fournisseur de divers nucléosides protégés et de partenaire pour la recherche sur les procédés.